Jimmy. wrote:It works out to be about $200 in fittings and such for the style stig put up.
lots of adapters for size changes as well
The Stig wrote:Jimmy. wrote:It works out to be about $200 in fittings and such for the style stig put up.
lots of adapters for size changes as well
Correct but gives me the ability to reconfigure with minimal fuss just like the still itself :handgestures-thumbupleft:
I’m sure it could be done much cheaper if you know somebody or aren’t worried about the change ability
RC Al wrote:Nice job mate.
Is that framed thing behind the still an uncut sheet of Jim beam labels? Cool mancave decoration. :handgestures-thumbupleft:
Jimmy. wrote:Finally set mine up after all the bits turned up.
I just used cheap garden hose for the testing of the unit as they didn't have 12mm internal hose in something more suitable.
I got the 1500lph https://www.bunnings.com.au/ozito-550w- ... p_p4816365
Does anyone run a second bleed on the pumps as the still wouldnt need the full 240lpm flow
hillzabilly wrote:I fitted a tee piece after the pump and befor the hose exits the coolant tank ,then fitted a valve off the tee wich when opened takes the pressure of the pump and circulates the coolant water in the tank,wich is handy ifn I am only running my 25lt set up on 900wt,then the valve is all open but with 80lt boiler with 3600wt its almost closed .cheers hillzabilly ;-)
EziTasting wrote:hillzabilly wrote:I fitted a tee piece after the pump and befor the hose exits the coolant tank ,then fitted a valve off the tee wich when opened takes the pressure of the pump and circulates the coolant water in the tank,wich is handy ifn I am only running my 25lt set up on 900wt,then the valve is all open but with 80lt boiler with 3600wt its almost closed .cheers hillzabilly ;-)
Not sure why, but this befuddles me... could you put up a picture/drawing...?
EziTasting wrote:hillzabilly wrote:I fitted a tee piece after the pump and befor the hose exits the coolant tank ,then fitted a valve off the tee wich when opened takes the pressure of the pump and circulates the coolant water in the tank,wich is handy ifn I am only running my 25lt set up on 900wt,then the valve is all open but with 80lt boiler with 3600wt its almost closed .cheers hillzabilly ;-)
Not sure why, but this befuddles me... could you put up a picture/drawing...?
timboss wrote:Great discussion Gents
I fired up the still for the first time in a few years and had the exact same thoughts about the braided lines. My goal is to use a pump that's a little less power hungry than the Ozito.
I have a bunch of PEX left over from a previous project, and it's rated for hot water, so I was going to give that a crack, but I think Matt_Pl's irrigation hose might be the way to go, and probably the cheapest options... Just with a couple strategically placed connectors or some sort to make it easy to dismantle... Just won't look very nice.
Return to Plated Column Stills