Boiler heat shroud

Boiler, burner and boiler modification talk.

Boiler heat shroud

Postby bt1 » Mon May 06, 2013 6:33 pm

Howdy,

Nothing new really but a timely reminder for established and pointer for new members.

Pre shroud:
Boiler: 50lt SS keg
Heat time: 1.25 hours
Wash:48lt
Run:2 - 2.5 hours
Gas: 3 burners rings used

With shroud
Boiler: 50lt SS keg
Heat time: approx 37mins
Wash:48lt
Run:1.5 hours
Gas:small ring and large ring on half

Cost $17 for drum (Paramounts if in SA), cutting disk existing, scrap R2.0 90mm Earthwool, Selleys liquid nails super set $7...should pay for itself in 2 gas bottles time :D

simple, quick saves you plenty. 50lt kegs are about 370mm wide, drum is 600mm insulation 90mm so 600 - (2 x 90mm) gives you a nice comfy fit. Won't worry about heat loss this winter.... as a guide I'm about to do spirit run 6 from same 9kg bottle. Tested with MAPP Pro 3700c+... flat stick with air hose flat can just induce smoulder but no ignition....bottle gas or even car LPG about 1900c so well good.

This is it after a few runs... good as new...
IMAG0008.jpg

IMAG0011.jpg


So now you have your winter keg cosy...get on with it and save ur self a few $ :handgestures-thumbupleft:

bt1
You do not have the required permissions to view the files attached to this post.
bt1
 
Posts: 2448
Joined: Sun Apr 22, 2012 11:56 am
Location: Adelaide
equipment: 2 x Glass Bubblers, 5 plate 89mm & 6 plate 110mm
4" 6 plate copper bubbler, 500mm copper packed section
Several pots, custom boiler
14 keg rotating brew setup, fermentation & dispenser fridges.

Re: Boiler heat shroud

Postby kelbygreen » Mon May 06, 2013 6:41 pm

nice idea :handgestures-thumbupleft:
kelbygreen
 
Posts: 191
Joined: Sat Sep 22, 2012 4:19 pm
Location: Newcastle
equipment: 3" pot

Re: Boiler heat shroud

Postby Brendan » Mon May 06, 2013 6:58 pm

If you're on electric, head to Clark Rubber and pick up a metre of the Silver/Black insatiable stuff ($20)...

Works ridiculously well, if I don't take it off, the boiler is still very hot 24 hours later. Perfect for a mash tun to hold the temp for an hour :handgestures-thumbupleft:
Brendan
 
Posts: 2154
Joined: Mon Nov 21, 2011 5:06 pm
Location: Hunter Valley, NSW
equipment: 4.99L Essential oil extractor

Re: Boiler heat shroud

Postby punchy21 » Mon May 06, 2013 7:25 pm

That's some impressive stats bt1! I might have to dress my boiler up in something warm coming into winter and all... I'm using electric so ill have to see what I can find. :handgestures-thumbupleft:
punchy21
 
Posts: 619
Images: 0
Joined: Fri Nov 04, 2011 11:56 am
Location: South West
equipment: Modular 4" 4 plate Bubbler
6kW 50L Boiler

Re: Boiler heat shroud

Postby Sam. » Mon May 06, 2013 8:35 pm

You cant argue with those results :handgestures-thumbupleft:
Sam.
Lifetime Member
 
Posts: 10405
Joined: Sun Jul 17, 2011 7:19 pm
Location: South Oz Straya
equipment: Original FSD 5 plate 4 inch modular bubbler SSG with hand crafted plates and parrot by Mac.
18 Gal boiler.
2 x 2400W elements and power controller.
.

Re: Boiler heat shroud

Postby bt1 » Sun May 12, 2013 8:24 am

Pictures worth plenty...

During run only the medium ring being used...love saving gas btw this was run #6 from same bottle...just scraped in.

IMAG0017.jpg


bt1
You do not have the required permissions to view the files attached to this post.
bt1
 
Posts: 2448
Joined: Sun Apr 22, 2012 11:56 am
Location: Adelaide
equipment: 2 x Glass Bubblers, 5 plate 89mm & 6 plate 110mm
4" 6 plate copper bubbler, 500mm copper packed section
Several pots, custom boiler
14 keg rotating brew setup, fermentation & dispenser fridges.

Re: Boiler heat shroud

Postby crow » Sun May 12, 2013 10:33 am

Good timing bt , was just telling my NIL about this last weekend, now I can direct him to this post
crow
 
Posts: 2363
Joined: Tue Mar 13, 2012 1:44 am
Location: Central Highlands Victoria
equipment: ultra pure reflux still and a 4" 4 plate MacStill built copper bubble cap column and a 500mm scoria packed rectifying module

Re: Boiler heat shroud

Postby Brendan » Sun May 12, 2013 10:38 am

I'm actually surprised that people are surprised by this...

I thought it was the standard idea that everyone wraps their boiler in some form of insulation?? Thought it was making a boiler 101...if not, you're losing a lot of heat and the whole process isn't very efficient.

Good reporting bt1... :handgestures-thumbupleft:
Brendan
 
Posts: 2154
Joined: Mon Nov 21, 2011 5:06 pm
Location: Hunter Valley, NSW
equipment: 4.99L Essential oil extractor

Re: Boiler heat shroud

Postby 1 2many » Wed May 15, 2013 4:20 pm

I agree very good savings on time and energy. Is that a 100 ltr drum ? And in the winter does anyone cover there bubbler or reflux column as well or only if out in a breeze. Cheers :handgestures-thumbupleft:
1 2many
Lifetime Member
 
Posts: 4217
Joined: Sun Jan 27, 2013 6:08 am
Location: Where the sun shines
equipment: Portable A.G brewery ,#001 5 STAR blockhead 4" Modular 4 plate SSG with,6"inline thumper, 2.5" 9 tube shotgun, packed section, Boiler 50 ltr inverted keg 4"still mount, 2.4 Kw FSD elements 1"drain.

Boiler heat shroud

Postby baldoss » Wed May 15, 2013 4:46 pm

Excellent post mate, definitely going to be setting one of these up!
baldoss
 
Posts: 158
Joined: Thu Feb 07, 2013 11:53 am
Location: Sydney, New South Wales
equipment: 2" copper pot still with liebig condenser on 50L ss keg boiler (gas)

Re: Boiler heat shroud

Postby adam89 » Wed May 22, 2013 2:14 pm

How have you found the Earth Wool is holding up after a few runs? Has it started to deteriorate?
adam89
 
Posts: 122
Joined: Thu Sep 20, 2012 2:38 pm
Location: Perth, NOR.
equipment: 2" Pot Still (Mac Built)
4" 5 Plate Modular Copper Bubbler (Mac Built)
50L Boiler on Gas
50L Boiler with 2x2400W element

Re: Boiler heat shroud

Postby bt1 » Wed May 22, 2013 4:05 pm

No issues Adam,

it doesn't seem to singe or oxidise ... I guess there are other better products around but this seems fine.... what I do like is only using 1 ring on the 3 ring burner and cutting out a tad under two hours.

cheers
bt1
bt1
 
Posts: 2448
Joined: Sun Apr 22, 2012 11:56 am
Location: Adelaide
equipment: 2 x Glass Bubblers, 5 plate 89mm & 6 plate 110mm
4" 6 plate copper bubbler, 500mm copper packed section
Several pots, custom boiler
14 keg rotating brew setup, fermentation & dispenser fridges.

Re: Boiler heat shroud

Postby drunkmore » Sun Aug 18, 2013 8:26 pm

Yup cutting two hours off run time has to be a good thing.
How is your burner getting air? I have same type. I would have thought that would starve, but obviously not.
drunkmore
 
Posts: 75
Joined: Wed Jul 24, 2013 5:20 pm
equipment: Pda1 over a 50ltr Keg cooled via recirculated 2000 ltr water tank
Cookan with Gass

Re: Boiler heat shroud

Postby bt1 » Mon Aug 19, 2013 7:53 am

The cut out for the burner stems/valves seems to enough, although it does sit on pavers and would most likely pull air through given the slightly uneven surface. A couple of pieces of flat steel would do the same if your concerned with it.

gas flame colour will tell you if it's pure orange it needs more air.

cheers
bt1
bt1
 
Posts: 2448
Joined: Sun Apr 22, 2012 11:56 am
Location: Adelaide
equipment: 2 x Glass Bubblers, 5 plate 89mm & 6 plate 110mm
4" 6 plate copper bubbler, 500mm copper packed section
Several pots, custom boiler
14 keg rotating brew setup, fermentation & dispenser fridges.

Re: Boiler heat shroud

Postby stretch69 » Wed Oct 02, 2013 11:41 am

That's awesome mate, do you use this with the bubbler?.
I've been looking for something like this, it would kind of make things a bit safer as well wouldn't it?
I'm only planning my bubbler at the moment but I've been worried about getting a leak or something and it catching on fire
stretch69
 
Posts: 293
Joined: Wed Sep 04, 2013 7:38 pm
Location: Adelaide - Northern Suburb's
equipment: 4" 4 plate FSD Bubbler!
50l Boiler