Postby bundy » Sun Sep 25, 2011 2:42 pm

my 1380w element is getting old and needs to be changed, 25l boiler. can i change to an 1800w element without having to use a controller and would it be of any advantage besides faster heat up.
bundy
 
Posts: 141
Joined: Sat Mar 19, 2011 7:54 am
Location: Nth.Qld.
equipment: Double reducer reflux still
pot still
both on 25lt electric boiler

Re: Element change

Postby SBB » Sun Sep 25, 2011 2:57 pm

Bundy my T500 boiler which is 25L runs 2000W.....I think QLD Andy's runs 2400-2500ish from memory.....both of these sizes work for reflux runs and stripping. Dont know how you'd go with a spirit run though
SBB
Lifetime Member
 
Posts: 2451
Joined: Mon Mar 21, 2011 8:12 pm
Location: Northern NSW
equipment: (The Pelican) a 2 inch pot / stripper on 25L electric boiler interchangable with T500 reflux still...... 2 1/2 inch pot still on 50L keg (gas burner).....
3 inch Boka (half share with Draino),...... 4 inch 4 plate perforated plate Bubbler

Re: Element change

Postby QLD.Andy » Sun Sep 25, 2011 6:27 pm

Its 2200 but from what we have found out at the LHBS its actually 2 elements wired to the 1 on off switch.
QLD.Andy
 
Posts: 724
Joined: Sat Mar 19, 2011 11:18 am
Location: andy.lives@qld.au/earth
equipment: Still Spirits T500 with Copper Mesh
McStill made Copper Parrot
McStill made Copper Pot Still

Re: Element change

Postby MacStill » Mon Sep 26, 2011 6:16 am

Bundy,

Your column is a small one that might struggle with too much heat thrown at it, if it worked well with 1380w I'd stick to that ;)

If you want faster heat up you could install a 2nd element and unplug it once upto running temp :)
MacStill
Lifetime Member
 
Posts: 16835
Joined: Fri Mar 18, 2011 1:40 pm
Location: Wide Bay QLD
equipment: Anything I choose :P

Re: Element change

Postby bundy » Mon Sep 26, 2011 7:11 am

thanks guys i will stick to 1380w works OK after 1 1/2 hrs warm up.
bundy
 
Posts: 141
Joined: Sat Mar 19, 2011 7:54 am
Location: Nth.Qld.
equipment: Double reducer reflux still
pot still
both on 25lt electric boiler

Re: Element change

Postby wynnum1 » Mon Sep 26, 2011 10:34 am

Now its getting warmer would putting wash in a car in the sun cut down on heat up time .
wynnum1
 
Posts: 1494
Joined: Tue Jul 26, 2011 1:18 pm

Re: Element change

Postby R-sole » Mon Sep 26, 2011 10:58 am

Dogs die in hot cars.
R-sole
 
Posts: 0
Joined: Mon Apr 18, 2011 4:15 am
Location: Northern NSW Australia
equipment: Keg based pot stiller. 3" vm for occasionally making product for macerations and redistillation.

Re: Element change

Postby bundy » Mon Sep 26, 2011 11:14 am

there's no problem i just thought that if i have to change element would i go for a bigger one. i will take advice given and stay with 1380w. time is not a problem, at my age it's all nice and slow. :lol:
i start warm up at 6am by the time I've had breky things are just about ready to go.
25l reflux run I'm finished by lunch time, stripping run finished by smoko.